The LPS Series
Overview (Standard and P Package Inverters) |
Parameter |
Symbol |
Units |
Code
D |
Code
1 |
Code
2 |
Code
3 |
Input Power per Unit Load |
Pin |
watts |
*0.200 |
*0.300 |
*0.400 |
*0.500 |
Minimum Input Voltage |
Vin(min) |
% |
-40 |
-40 |
-40 |
-40 |
Maximum Input Voltage |
Vin(max) |
% |
25 |
25 |
25 |
25 |
Minimum Operating Temperature |
T(min) |
C |
-25 |
-25 |
-25 |
-25 |
Maximum Operating Temperature |
T(max) |
C |
85 |
85 |
85 |
85 |
Nominal Output Voltage |
Vout |
Vrms |
60 |
80 |
100 |
120 |
Nominal Operating Frequency |
Fout |
Hz |
400 |
400 |
400 |
400 |
Maximum Number of Unit Loads |
Lmax |
-- |
17 |
10 |
7 |
5 |
Output Voltage Tolerance |
- |
% |
+10 |
+10 |
+10 |
+10 |
Operating Frequency Tolerance |
- |
% |
+10 |
+10 |
+10 |
+10 |
Output Current per Unit Load |
Iout |
marms |
3.1 |
4.1 |
5.1 |
6.2 |
* Input
power may increase by 10% on low input voltage and/or single unit load inverters |
The LPS Series
Unit Load |
|
|
Each Unit Load
C = .02 uf